Class=10 (0x0A) - Measurement

CLASS1.MEASUREMENT

Description

Measurements are fetched from the SI units and from SI derived units. The SI unit (or the SI derived unit) is also used as the default unit. As in the SI unit standard, names for a unit is in lower case ("newton") and the unit ("N") is in upper case.

Byte 0 is the data coding byte for all measurement packages. The default unit has bits 0,1,2 set to 000 and the first optional unit 001 and so on. It also have a field for the item ( if more than one sensor is controlled by the node) that the value belongs to. See data-coding for a full description on data coding used.

All events in this class are mirrored in CLASS1.MEASUREMENT32=70 (0x46) as a single precision float. Default unit is used.

All events in this class are mirrored in CLASS1.MEASUREMENT64=60 (0x3C) as floating point values using only the default unit .

All events in this class are mirrored in CLASS1.MEASUREZONE=65 (0x41) as normalized integer values with index, zone, sub-zone. Default unit is used.

All events in this class are mirrored in CLASS1.SETVALUEZONE=85 (0x55) as a normalized value using only the default unit but with index/zone/subzone.

All of the above is also available as LEVEL I events over Level II.

All events in this class are mirrored in CLASS2.MEASUREMENT_STR=1040 (0x410) which use decimal string values.

All events in this class are mirrored in CLASS2.MEASUREMENT_FLOAT=1060 (0x424) which use decimal float values.

Type=0 (0x00) - General event

VSCP_TYPE_MEASUREMENT_GENERAL

General Event.

Type=1 (0x01) - Count

VSCP_TYPE_MEASUREMENT_COUNT

This is a discrete value typical for a count. There is no unit for this measurement just a discrete value.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=2 (0x02) - Length/Distance

VSCP_TYPE_MEASUREMENT_LENGTH

Default unit: Meter.

This is a measurement of a length or a distance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=3 (0x03) - Mass

VSCP_TYPE_MEASUREMENT_MASS

Default unit: Kilogram.

This is a measurement of a mass.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=4 (0x04) - Time

VSCP_TYPE_MEASUREMENT_TIME

A time measurement.

Default unit: Seconds.
Opt. unit: (1) Milliseconds. Absolute: (2) y-y-m-d-h-m-s (binary). String: (3) "HHMMSS".

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=5 (0x05) - Electric Current

VSCP_TYPE_MEASUREMENT_ELECTRIC_CURRENT

Default unit: Ampere.

This is a measurement of an electric current.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=6 (0x06) - Temperature

VSCP_TYPE_MEASUREMENT_TEMPERATURE

Default unit: Kelvin.
Opt. unit: Degree Celsius (1), Fahrenheit (2)

This is a measurement of a temperature.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=7 (0x07) - Amount of substance

VSCP_TYPE_MEASUREMENT_AMOUNT_OF_SUBSTANCE

Default unit: Mole.

This is a measurement of an amount of a substance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=8 (0x08) - Luminous Intensity (Intensity of light)

VSCP_TYPE_MEASUREMENT_INTENSITY_OF_LIGHT

Default unit: Candela.

This is a measurement of luminous intensity.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=9 (0x09) - Frequency

VSCP_TYPE_MEASUREMENT_FREQUENCY

Default unit: Hertz.

This is a measurement of regular events during a second.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=10 (0x0A) - Radioactivity and other random events

VSCP_TYPE_MEASUREMENT_RADIOACTIVITY

Default unit: becquerel. Optional unit: curie (1)

This is a measurement of rates of things, which happen randomly, or are unpredictable.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=11 (0x0B) - Force

VSCP_TYPE_MEASUREMENT_FORCE

Default unit: newton.

This is a measurement of force.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=12 (0x0C) - Pressure

VSCP_TYPE_MEASUREMENT_PRESSURE

Default unit: pascal.
Opt. unit: bar (1), psi (2)

This is a measurement of pressure.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=13 (0x0D) - Energy

VSCP_TYPE_MEASUREMENT_ENERGY

Default unit: Joule.
Optional unit: KWh (1)

This is a measurement of energy.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=14 (0x0E) - Power

VSCP_TYPE_MEASUREMENT_POWER

Default unit: watt.
Optional unit: Horse power (1).

This is a measurement of power.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=15 (0x0F) - Electrical Charge

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CHARGE

Default unit: coulomb.

This is a measurement electrical charge.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=16 (0x10) - Electrical Potential (Voltage)

VSCP_TYPE_MEASUREMENT_ELECTRICAL_POTENTIAL

Default unit: volt.

This is a measurement of electrical potential.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=17 (0x11) - Electrical Capacitance

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CAPACITANCE

Default unit: farad (F).

This is a measurement of electric capacitance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=18 (0x12) - Electrical Resistance

VSCP_TYPE_MEASUREMENT_ELECTRICAL_RESISTANCE

Default unit: ohm (Ω).

This is a measurement of resistance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=19 (0x13) - Electrical Conductance

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CONDUCTANCE

Default unit: siemens.

This is a measurement of electrical conductance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=20 (0x14) - Magnetic Field Strength

VSCP_TYPE_MEASUREMENT_MAGNETIC_FIELD_STRENGTH

Default unit: amperes per meter (H).
Optional units: teslas (B) (1)

This is a measurement of magnetic field strength.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=21 (0x15) - Magnetic Flux

VSCP_TYPE_MEASUREMENT_MAGNETIC_FLUX

Default unit: weber (Wb).

This is a measurement of magnetic flux.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=22 (0x16) - Magnetic Flux Density

VSCP_TYPE_MEASUREMENT_MAGNETIC_FLUX_DENSITY

Default unit: tesla (B).

This is a measurement of flux density or field strength for magnetic fields (also called the magnetic induction).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=23 (0x17) - Inductance

VSCP_TYPE_MEASUREMENT_INDUCTANCE

Default unit: henry (H).

This is a measurement of inductance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=24 (0x18) - Luminous Flux

VSCP_TYPE_MEASUREMENT_FLUX_OF_LIGHT

Default unit: Lumen (lm= cd * sr)

This is a measurement of luminous Flux.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=25 (0x19) - Illuminance

VSCP_TYPE_MEASUREMENT_ILLUMINANCE

Default unit: lux (lx) ( lx = lm / m² )

This is used to express both Illuminance (incidence of light) and Luminous Emittance (emission of light).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=26 (0x1A) - Radiation dose

VSCP_TYPE_MEASUREMENT_RADIATION_DOSE

Default unit: gray (Gy).
Opt unit: sievert (Sv) (1).

This is a measurement of a radiation dose (Absorbed dose of ionizing radiation).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=27 (0x1B) - Catalytic activity

VSCP_TYPE_MEASUREMENT_CATALYTIC_ACITIVITY

Default unit: katal (z).

This is a measurement of catalytic activity used in biochemistry.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=28 (0x1C) - Volume

VSCP_TYPE_MEASUREMENT_VOLUME

Default unit: cubic meter (m³)
Opt. unit: Liter (dm³) (1), decilitre (100 cm³) (2), centilitre (10 cm³) (3), millilitre (cm³) (4) where unit 4 is only available for Level II measurement events where units can hold this value.

This is a measurement of volume.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=29 (0x1D) - Sound intensity

VSCP_TYPE_MEASUREMENT_SOUND_INTENSITY

Default unit: W/m2, watt per square meter.

This is a measurement of sound intensity (acoustic intensity).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=30 (0x1E) - Angle

VSCP_TYPE_MEASUREMENT_ANGLE
  • Default unit: radian (rad) (Plane angles).
  • Opt Unit: degree (1).
  • Opt Unit: arcminute (2).
  • Opt Unit: arcseconds (3).

This is a measurement of an angle.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=31 (0x1F) - Position WGS 84

VSCP_TYPE_MEASUREMENT_POSITION

Default unit: Longitude.
Opt. unit: Latitude.

This is a measurement of a position as of WGS 84. Normally given as a floating point value. See ./class1.gps.md for a better candidate to use for position data.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=32 (0x20) - Speed

VSCP_TYPE_MEASUREMENT_SPEED

Default unit: Meters per second.
Optional unit: Kilometers per hour (1) Miles per hour (2)

This is a measurement of a speed.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=33 (0x21) - Acceleration

VSCP_TYPE_MEASUREMENT_ACCELERATION

Default unit: Meters per second/second (m/s2).

This is a measurement of acceleration.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=34 (0x22) - Tension

VSCP_TYPE_MEASUREMENT_TENSION

Default unit: N/m.

This is a measurement of tension.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=35 (0x23) - Damp/moist (Hygrometer reading)

VSCP_TYPE_MEASUREMENT_HUMIDITY

Default unit: Relative percentage 0-100%.

This is a measurement of relative moistness (Humidity).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=36 (0x24) - Flow

VSCP_TYPE_MEASUREMENT_FLOW

Default unit: Cubic meters/second.
Opt Unit: Liters/Second.

This is a measurement of flow.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=37 (0x25) - Thermal resistance

VSCP_TYPE_MEASUREMENT_THERMAL_RESISTANCE

Default unit: Thermal ohm K/W.

This is a measurement of thermal resistance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=38 (0x26) - Refractive (optical) power

VSCP_TYPE_MEASUREMENT_REFRACTIVE_POWER

Default unit: dioptre (dpt) m-1.

This is a measurement of refractive (optical) power.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=39 (0x27) - Dynamic viscosity

VSCP_TYPE_MEASUREMENT_DYNAMIC_VISCOSITY

Default unit: poiseuille (Pl)

This is a measurement of dynamic viscosity.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=40 (0x28) - Sound impedance

VSCP_TYPE_MEASUREMENT_SOUND_IMPEDANCE

Default unit: rayl (Pa·s/m)

This is a measurement of sound impedance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=41 (0x29) - Sound resistance

VSCP_TYPE_MEASUREMENT_SOUND_RESISTANCE

Default unit: Acoustic ohm Pa · s/ m³.

This is a measurement of sound resistance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=42 (0x2A) - Electric elastance

VSCP_TYPE_MEASUREMENT_ELECTRIC_ELASTANCE

Default unit: daraf (f-1).

This is a measurement of electric elasticity.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=43 (0x2B) - Luminous energy

VSCP_TYPE_MEASUREMENT_LUMINOUS_ENERGY

Default unit: talbot ( tb = lm * s)

This is a measurement of luminous energy.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=44 (0x2C) - Luminance

VSCP_TYPE_MEASUREMENT_LUMINANCE

Default unit: cd / m²) (non SI unit = nit)

This is a measurement of luminance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=45 (0x2D) - Chemical concentration

VSCP_TYPE_MEASUREMENT_CHEMICAL_CONCENTRATION

Default unit: molal (mol/kg).

This is a measurement of chemical concentration.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=46 (0x2E) - Reserved

VSCP_TYPE_MEASUREMENT_RESERVED46

Reserved (previously was doublet of Type= 26, don't use any longer!)


Type=47 (0x2F) - Dose equivalent

VSCP_TYPE_MEASUREMENT_DOSE_EQVIVALENT

Default unit: sievert (J/Kg).

This is a measurement of dose equivalent.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=48 (0x30) - Reserved

VSCP_TYPE_MEASUREMENT_RESERVED48

Reserved (was doublet of Type= 24, do not use any longer!)


Type=49 (0x31) - Dew Point

VSCP_TYPE_MEASUREMENT_DEWPOINT

Default unit: Kelvin.
Opt. unit: Degree Celsius (1), Fahrenheit (2)

This is a measurement of the Dew Point.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=50 (0x32) - Relative Level

VSCP_TYPE_MEASUREMENT_RELATIVE_LEVEL

Default unit: Relative value.

This is a relative value for a level measurement without a unit. It is just relative to the min/max value for the selected data representation, typically percentage or per mille or similar.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=51 (0x33) - Altitude

VSCP_TYPE_MEASUREMENT_ALTITUDE

Default unit: Meter.
Opt. unit: Feet(1), inches (2)

Altitude in meters.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=52 (0x34) - Area

VSCP_TYPE_MEASUREMENT_AREA

Default unit: square meter (m²)

Area in square meter.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=53 (0x35) - Radiant intensity

VSCP_TYPE_MEASUREMENT_RADIANT_INTENSITY

Default unit: watt per steradian ( W / sr )

Radiated power per room angle.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=54 (0x36) - Radiance

VSCP_TYPE_MEASUREMENT_RADIANCE

Default unit: watt per steradian per square metre ( W / (sr * m²) )

This is the radiant flux emitted, reflected, transmitted or received by a surface.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=55 (0x37) - Irradiance, Exitance, Radiosity

VSCP_TYPE_MEASUREMENT_IRRADIANCE

Default unit: watt per square metre ( W / m² )

Power emitted from or striking onto a surface or area.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=56 (0x38) - Spectral radiance

VSCP_TYPE_MEASUREMENT_SPECTRAL_RADIANCE

Default unit: watt per steradian per square metre per nm (W·sr-1·m-2·nm-1)
Opt. unit: watt per steradian per meter3 (W·sr-1·m-3) (1), watt per steradian per square metre per hertz (W·sr-1·m-3) (2)

Radiance of a surface per unit frequency or wavelength.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=57 (0x39) - Spectral irradiance

VSCP_TYPE_MEASUREMENT_SPECTRAL_IRRADIANCE

Default unit: watt per square metre per nm (W·m-2·nm-1)
Opt. unit: watt per metre3 (W·m-3) (1), watt per square metre per hertz (W·m-2·Hz-1) (2)

Irradiance of a surface per unit frequency or wavelength.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=58 (0x3A) - Sound pressure (acoustic pressure)

VSCP_TYPE_MEASUREMENT_SOUND_PRESSURE

Default unit: pascal (Pa)

This is a measurement of sound pressure (acoustic pressure).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=59 (0x3B) - Sound energy density

VSCP_TYPE_MEASUREMENT_SOUND_DENSITY

Default unit: pascal (Pa)

Sound energy density or sound density is the sound energy per unit volume.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=60 (0x3C) - Sound level

VSCP_TYPE_MEASUREMENT_SOUND_LEVEL

Default unit: decibel (dB)

Sound level expressed in decibel. This event is supplied for convenience.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.


Very Simple Control Protocol