Class=513 (0x0201) - Class2 Level I Alarm

CLASS2.LEVEL1.ALARM

Description

This class mirrors the CLASS1.ALARM class but use a different data format with a GUID stored in the first 16 bytes of the data followed by the standard data thus offset with 16-bytes.

See CLASS2.PROTOCOL1 for more information on the data format.

Type=0 (0x00) - General event

VSCP_TYPE_ALARM_GENERALGeneral Event. 

Type=1 (0x01) - Warning

VSCP_TYPE_ALARM_WARNINGIndicates a warning condition. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=2 (0x02) - Alarm occurred

VSCP_TYPE_ALARM_ALARMIndicates an alarm condition. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=3 (0x03) - Alarm sound on/off

VSCP_TYPE_ALARM_SOUNDAlarm sound should be turned on or off. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=4 (0x04) - Alarm light on/off

VSCP_TYPE_ALARM_LIGHTAlarm light should be turned on or off. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=5 (0x05) - Power on/off

VSCP_TYPE_ALARM_POWERPower has been lost or is available again. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=6 (0x06) - Emergency Stop

VSCP_TYPE_ALARM_EMERGENCY_STOPEmergency stop has been hit/activated. All systems on the zone/sub-zone should go to their inactive/safe state.
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=7 (0x07) - Emergency Pause

VSCP_TYPE_ALARM_EMERGENCY_PAUSEEmergency pause has been hit/activated. All systems on the zone/sub-zone should go to their inactive/safe state but preserve there settings. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all subzones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=8 (0x08) - Emergency Reset

VSCP_TYPE_ALARM_EMERGENCY_RESETIssued after an emergency stop or pause in order for nodes to reset and start operating .
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=9 (0x09) - Emergency Resume

VSCP_TYPE_ALARM_EMERGENCY_RESUMEIssued after an emergency pause in order for nodes to start operating from where they left of without resetting their registers . 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=10 (0x0A) - Arm

VSCP_TYPE_ALARM_ARMIssued after an alarm system has been armed. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.


Type=11 (0x0B) - Disarm

VSCP_TYPE_ALARM_DISARMIssued after an alarm system has been disarmed. 
Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.