Class=1040 (0x0410) - Measurement string

CLASS2.MEASUREMENT_STR

Description

This is a mirror of CLASS1_MEASUREMENT where the data is in string form. The zero terminated string has the following form “sensor-index, value-unit, zone, subzone, value” where the value is a floating point value in string form and the senor-index and value-unit is the same as for CLASS1_MEASUREMENT but where sensor index's can be in the range 0-255 and value-unit in the range 0-255 (3 is standard).

Floating point numbers should be written as "2345.456" NOT as "2345,456" independent of locale and the maximum number can have 483 digits including a possible decimal point.

Byte Description
0 Index for sensor, 0-255.
1 Zone, 0-255.
2 Subzone, 0-255.
3 Unit from measurements, 0-255.
4.. String up to the maximum data size 483 digits including a possible decimal point. The decimal pint should always be a "." independent of locale.

Type=0 (0x00) - General event

VSCP_TYPE_MEASUREMENT_GENERALGeneral Event.

Type=1 (0x01) - Count

VSCP_TYPE_MEASUREMENT_COUNTThis is a discrete value typical for a count. There is no unit for this measurement just a discrete value. 
Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=2 (0x02) - Length/Distance

VSCP_TYPE_MEASUREMENT_LENGTH**Default unit:** Meter. 

This is a measurement of a length or a distance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=3 (0x03) - Mass

VSCP_TYPE_MEASUREMENT_MASS**Default unit:** Kilogram.

This is a measurement of a mass.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=4 (0x04) - Time

VSCP_TYPE_MEASUREMENT_TIMEA time measurement.

Default unit: Seconds.
Opt. unit: (1) Milliseconds. Absolute: (2) y-y-m-d-h-m-s (binary). String: (3) "HHMMSS".

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=5 (0x05) - Electric Current

VSCP_TYPE_MEASUREMENT_ELECTRIC_CURRENT**Default unit:** Ampere.

This is a measurement of an electric current.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=6 (0x06) - Temperature

VSCP_TYPE_MEASUREMENT_TEMPERATURE**Default unit:** Kelvin.  

Opt. unit: Degree Celsius (1), Fahrenheit (2)

This is a measurement of a temperature.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=7 (0x07) - Amount of substance

VSCP_TYPE_MEASUREMENT_AMOUNT_OF_SUBSTANCE**Default unit:** Mole.

This is a measurement of an amount of a substance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=8 (0x08) - Luminous Intensity (Intensity of light)

VSCP_TYPE_MEASUREMENT_INTENSITY_OF_LIGHT**Default unit:** Candela.

This is a measurement of luminous intensity.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=9 (0x09) - Frequency

VSCP_TYPE_MEASUREMENT_FREQUENCY

Default unit: Hertz.

This is a measurement of regular events during a second.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=10 (0x0A) - Radioactivity and other random events

VSCP_TYPE_MEASUREMENT_RADIOACTIVITY**Default unit:** becquerel.

Optional unit: curie (1)

This is a measurement of rates of things, which happen randomly, or are unpredictable.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=11 (0x0B) - Force

VSCP_TYPE_MEASUREMENT_FORCE**Default unit:** newton.

This is a measurement of force.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=12 (0x0C) - Pressure

VSCP_TYPE_MEASUREMENT_PRESSURE**Default unit:** pascal.  

Opt. unit: bar (1), psi (2)

This is a measurement of pressure.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=13 (0x0D) - Energy

VSCP_TYPE_MEASUREMENT_ENERGY**Default unit:** Joule.  

Optional unit: KWh (1)

This is a measurement of energy.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=14 (0x0E) - Power

VSCP_TYPE_MEASUREMENT_POWER**Default unit:** watt.  

Optional unit: Horse power (1).

This is a measurement of power.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=15 (0x0F) - Electrical Charge

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CHARGE**Default unit:** coulomb.

This is a measurement electrical charge.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=16 (0x10) - Electrical Potential (Voltage)

VSCP_TYPE_MEASUREMENT_ELECTRICAL_POTENTIAL**Default unit:** volt.

This is a measurement of electrical potential.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=17 (0x11) - Electrical Capacitance

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CAPACITANCE**Default unit:** farad (F).

This is a measurement of electric capacitance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=18 (0x12) - Electrical Resistance

VSCP_TYPE_MEASUREMENT_ELECTRICAL_RESISTANCE**Default unit:** ohm (Ω).

This is a measurement of resistance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=19 (0x13) - Electrical Conductance

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CONDUCTANCE**Default unit:** siemens.

This is a measurement of electrical conductance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=20 (0x14) - Magnetic Field Strength

VSCP_TYPE_MEASUREMENT_MAGNETIC_FIELD_STRENGTH**Default unit:** amperes per meter (H).  

Optional units: teslas (B) (1)

This is a measurement of magnetic field strength.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=21 (0x15) - Magnetic Flux

VSCP_TYPE_MEASUREMENT_MAGNETIC_FLUX**Default unit:** weber (Wb).

This is a measurement of magnetic flux.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=22 (0x16) - Magnetic Flux Density

VSCP_TYPE_MEASUREMENT_MAGNETIC_FLUX_DENSITY**Default unit:** tesla (B).

This is a measurement of flux density or field strength for magnetic fields (also called the magnetic induction).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=23 (0x17) - Inductance

VSCP_TYPE_MEASUREMENT_INDUCTANCE**Default unit:** henry (H).

This is a measurement of inductance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=24 (0x18) - Luminous Flux

VSCP_TYPE_MEASUREMENT_FLUX_OF_LIGHT**Default unit:** Lumen (lm= cd * sr)

This is a measurement of luminous Flux.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=25 (0x19) - Illuminance

VSCP_TYPE_MEASUREMENT_ILLUMINANCE**Default unit:** lux (lx) ( lx = lm / m² )

This is used to express both Illuminance (incidence of light) and Luminous Emittance (emission of light).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=26 (0x1A) - Radiation dose

VSCP_TYPE_MEASUREMENT_RADIATION_DOSE**Default unit:** gray (Gy).   

Opt unit: sievert (Sv) (1).

This is a measurement of a radiation dose (Absorbed dose of ionizing radiation).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=27 (0x1B) - Catalytic activity

VSCP_TYPE_MEASUREMENT_CATALYTIC_ACITIVITY**Default unit:** katal (z).

This is a measurement of catalytic activity used in biochemistry.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=28 (0x1C) - Volume

VSCP_TYPE_MEASUREMENT_VOLUME**Default unit:** cubic meter (m³)   

Opt. unit: Liter (dm³) (1), decilitre (100 cm³) (2), centilitre (10 cm³) (3), millilitre (cm³) (4) where unit 4 is only available for Level II measurement events where units can hold this value.

This is a measurement of volume.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=29 (0x1D) - Sound intensity

VSCP_TYPE_MEASUREMENT_SOUND_INTENSITY**Default unit:** W/m2, watt per square meter. 

This is a measurement of sound intensity (acoustic intensity).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=30 (0x1E) - Angle

VSCP_TYPE_MEASUREMENT_ANGLE* **Default unit:** radian (rad) (Plane angles).   
  • Opt Unit: degree (1).
  • Opt Unit: arcminute (2).
  • Opt Unit: arcseconds (3).

This is a measurement of an angle.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=31 (0x1F) - Position WGS 84

VSCP_TYPE_MEASUREMENT_POSITION**Default unit:** Longitude.  

Opt. unit: Latitude.

This is a measurement of a position as of WGS 84. Normally given as a floating point value. See ./class1.gps.md for a better candidate to use for position data.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=32 (0x20) - Speed

VSCP_TYPE_MEASUREMENT_SPEED**Default unit:** Meters per second.   

Optional unit: Kilometers per hour (1) Miles per hour (2)

This is a measurement of a speed.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=33 (0x21) - Acceleration

VSCP_TYPE_MEASUREMENT_ACCELERATION**Default unit:** Meters per second/second (m/s2).

This is a measurement of acceleration.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=34 (0x22) - Tension

VSCP_TYPE_MEASUREMENT_TENSION**Default unit:** N/m.

This is a measurement of tension.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=35 (0x23) - Damp/moist (Hygrometer reading)

VSCP_TYPE_MEASUREMENT_HUMIDITY**Default unit:** Relative percentage 0-100%.

This is a measurement of relative moistness (Humidity).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=36 (0x24) - Flow

VSCP_TYPE_MEASUREMENT_FLOW**Default unit:** Cubic meters/second.   

Opt Unit: Liters/Second.

This is a measurement of flow.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=37 (0x25) - Thermal resistance

VSCP_TYPE_MEASUREMENT_THERMAL_RESISTANCE**Default unit:** Thermal ohm K/W.

This is a measurement of thermal resistance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=38 (0x26) - Refractive (optical) power

VSCP_TYPE_MEASUREMENT_REFRACTIVE_POWER**Default unit:** dioptre (dpt) m-1.

This is a measurement of refractive (optical) power.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=39 (0x27) - Dynamic viscosity

VSCP_TYPE_MEASUREMENT_DYNAMIC_VISCOSITY**Default unit:** poiseuille (Pl) 

This is a measurement of dynamic viscosity.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=40 (0x28) - Sound impedance

VSCP_TYPE_MEASUREMENT_SOUND_IMPEDANCE**Default unit:** rayl (Pa·s/m)

This is a measurement of sound impedance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=41 (0x29) - Sound resistance

VSCP_TYPE_MEASUREMENT_SOUND_RESISTANCE**Default unit:** Acoustic ohm Pa · s/ m³.

This is a measurement of sound resistance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=42 (0x2A) - Electric elastance

VSCP_TYPE_MEASUREMENT_ELECTRIC_ELASTANCE**Default unit:** daraf (f-1).

This is a measurement of electric elasticity.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=43 (0x2B) - Luminous energy

VSCP_TYPE_MEASUREMENT_LUMINOUS_ENERGY**Default unit:** talbot ( tb = lm * s) 

This is a measurement of luminous energy.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=44 (0x2C) - Luminance

VSCP_TYPE_MEASUREMENT_LUMINANCE**Default unit:** cd / m²) (non SI unit = nit)

This is a measurement of luminance.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=45 (0x2D) - Chemical concentration

VSCP_TYPE_MEASUREMENT_CHEMICAL_CONCENTRATION**Default unit:** molal (mol/kg).

This is a measurement of chemical concentration.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=46 (0x2E) - Reserved

VSCP_TYPE_MEASUREMENT_RESERVED46Reserved (previously was doublet of Type= 26, don't use any longer!) 

Type=47 (0x2F) - Dose equivalent

VSCP_TYPE_MEASUREMENT_DOSE_EQVIVALENT**Default unit:** sievert (J/Kg).

This is a measurement of dose equivalent.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=48 (0x30) - Reserved

VSCP_TYPE_MEASUREMENT_RESERVED48Reserved (was doublet of Type= 24, do not use any longer!)

Type=49 (0x31) - Dew Point

VSCP_TYPE_MEASUREMENT_DEWPOINT**Default unit:** Kelvin.  

Opt. unit: Degree Celsius (1), Fahrenheit (2)

This is a measurement of the Dew Point.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=50 (0x32) - Relative Level

VSCP_TYPE_MEASUREMENT_RELATIVE_LEVEL**Default unit:** Relative value.

This is a relative value for a level measurement without a unit. It is just relative to the min/max value for the selected data representation, typically percentage or per mille or similar.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=51 (0x33) - Altitude

VSCP_TYPE_MEASUREMENT_ALTITUDE**Default unit:** Meter.  

Opt. unit: Feet(1), inches (2)

Altitude in meters.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=52 (0x34) - Area

VSCP_TYPE_MEASUREMENT_AREA**Default unit:** square meter (m²)

Area in square meter.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=53 (0x35) - Radiant intensity

VSCP_TYPE_MEASUREMENT_RADIANT_INTENSITY**Default unit:** watt per steradian ( W / sr )

Radiated power per room angle.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=54 (0x36) - Radiance

VSCP_TYPE_MEASUREMENT_RADIANCE**Default unit:** watt per steradian per square metre ( W / (sr * m²) )

This is the radiant flux emitted, reflected, transmitted or received by a surface.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=55 (0x37) - Irradiance, Exitance, Radiosity

VSCP_TYPE_MEASUREMENT_IRRADIANCE**Default unit:** watt per square metre ( W / m² )

Power emitted from or striking onto a surface or area.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=56 (0x38) - Spectral radiance

VSCP_TYPE_MEASUREMENT_SPECTRAL_RADIANCE**Default unit:** watt per steradian per square metre per nm (W·sr-1·m-2·nm-1)    

Opt. unit: watt per steradian per meter3 (W·sr-1·m-3) (1), watt per steradian per square metre per hertz (W·sr-1·m-3) (2)

Radiance of a surface per unit frequency or wavelength.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=57 (0x39) - Spectral irradiance

VSCP_TYPE_MEASUREMENT_SPECTRAL_IRRADIANCE**Default unit:** watt per square metre per nm (W·m-2·nm-1)   

Opt. unit: watt per metre3 (W·m-3) (1), watt per square metre per hertz (W·m-2·Hz-1) (2)

Irradiance of a surface per unit frequency or wavelength.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=58 (0x3A) - Sound pressure (acoustic pressure)

VSCP_TYPE_MEASUREMENT_SOUND_PRESSURE**Default unit:** pascal (Pa) 

This is a measurement of sound pressure (acoustic pressure).

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=59 (0x3B) - Sound energy density

VSCP_TYPE_MEASUREMENT_SOUND_DENSITY**Default unit:** pascal (Pa) 

Sound energy density or sound density is the sound energy per unit volume.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.

Type=60 (0x3C) - Sound level

VSCP_TYPE_MEASUREMENT_SOUND_LEVEL**Default unit:** decibel (dB) 

Sound level expressed in decibel. This event is supplied for convenience.

Data byte Description
0 Data coding.
1-7 Data with format defined by byte 0.


Very Simple Control Protocol
Thu Oct 18 2018 14:14:05 GMT+0000 (UTC)
This document is licensed under Creative Commons BY 4.0 and can be freely copied, redistributed, remixed, transformed, built upon as long as you give credits to the author.

results matching ""